PQE Power Quality Analyzer (G4000 series)
PQE Power Quality Analyzer (G4000 series) Panel Mounted Power Quality Analyzer Power Quality Analyzer Power Quality Measurement Solutions Selangor, Malaysia, Kuala Lumpur (KL), Petaling Jaya (PJ) Services | PQE Power System Sdn Bhd
Download Files
PQE_POWER_QUALITY_ANALYZER.pdf (2.7 MB)

PQE Power Quality Analyzer G4400 Series is the best PQ analyzer in the market today as it is equipped with the revolutionary PQZIP patent algorithm for continuous waveform recording. This most advanced analyzer enables you to predict, prevent and troubleshoot an incidence easily, without the need to set any trigger or threshold in order to capture a specific event.


FEATURES

PQZIP inside

  • Continuous waveform recording
  • Trigger free setup
  • 5,000 power parameters @ 1/2 cycle resolution
  • Easy deployment 


Class A
Far surpassing the highest standards set by the industry, the BLACKBOX device series complies with standards for: aggregations, time clock uncertainty, flagging, and transient influence quantities.
 
Superior Accuracy
PQE’s pioneering measurement method utilizes a dual-range gain of 2 x 16 Bit to yield, a superior accuracy far surpassing IEC 61000-4-30 Class A requirements, thereby capturing the finest details & deviations in Power Quality parameters.
 
Synchronized Monitoring
A unique time synchronization algorithm assures that logged data from multiple units is synchronized & displayed on the same time scale with typical 0.1 ms resolution. Every event on a grid is accurately analyzed for precise root cause analysis, behaviour propagation, and traced to its source

  • Continuous waveform recording
  • Trigger free setup
  • 5,000 power parameters @ 1/2 cycle resolution
  • Easy deployment

 

APPLICATIONS

Utilities (transmission, distribution, generation)

  • Optimizes protective equipment configuration and substation automation solutions
  • Ensures a reliable and consistent supply of energy
  • Evaluates the performance of breakers and relays
  • Identifies and manage peak demand
  • Real time power quality monitoring to meet any international standard
  • Produces detailed & comprehensive statistical records

Energy consumer (critical power, industrial, commercial, etc.)

  • Measures and analyzes system efficiency, provides solutions and increases profits
  • Negotiates capabilities with power providers
  • Detects electric bill inconsistencies
  • Avoids power quality compliance issues
  • Monitors and analyze power quality in real time


SPECIFICATIONS

 

Product Series

G4410

G4420

G4430

Voltage Sampling Rate, Maximum Samples/Cycle

256

512

1,024

Voltage Harmonics (Individual, Even, Odd, Total) Up to –

127TH

255th

511th

Type of Analog to Digital Converter

16/201 bit

16/201 bit

16/201 bit

Internal Memory

128 MB

4 GB

16 GB

Transient Detection, Microseconds (50Hz/60Hz)

78.1/65.1μs

39/32.5μs

19.5/16.3μs

Ethernet Ports

1

2

2

Power Over Ethernet (PoE- Out)

1

1

Voltage Ride Through on Power Loss (up to)

10 sec.

25 sec.

25 sec.

Applicable Measurement Standards

EN50160, IEEE1159, IEEE519, IEC61000-4-15,IEC61000-4-7, IEC61000-4-30 Class A,IEC62053-22/23 Class 0.2

Applicable EMC Standards

EN55011 Group 1 Class A, EN61000-6-2, IEC60255EN60439-1 (clauses 7.9.1, 7.9.3, 7.9.4, 7.10.3, 7.10.4),FCC Part 15 Subpart B Class A, IEC61000-3-3

Voltage Channels

Channels

3 Phase + Neutral

Nominal Full Scale

1,000V

Maximum Peak Measurement

8kV

Input Impedance

3MΩ

Uncertainty

0.1% of Nominal

Current Channels

Channels

3 Phase + Neutral

Nominal Full Scale

5A

Maximum Peak Measurement

50A

Burden

0.0001VA@5A

Phase

±0.42°@3A ±0.17°@5A

Uncertainty

0.1% of Nominal

Frequency Measurement

Fundamental Frequency

42.5 Hz to 69 Hz

Frequency Resolution

10 mHz

Frequency Accuracy

±10 mHz

Physical

Dimensions

175mm x 232mm x138mm

Weight

1.7Kg

Power Supply

Operating Range

100-260 VAC: 50/60 Hz 100-300 VDC

Auxiliary DC Supply

48 VDC

Auxiliary Supply – PoE In

PoE In According to 802.3af

Time Synchronization

Real Time Clock

20ppm

GPS

100-200μs

IRIG B

100-200μs

SNTP Server

50-100μs

DCF-77

±15ms

Environmental Conditions

Operation Temperature

 -20°C to 70°C(-4°F to 158°F)

Storage Temperature

-40°C to 85°C(-40°F to 185°F)

 

For all your power quality monitoring needs, contact us today and discover the latest solutions on offer. Our experienced team can guide you in selecting the best solution for your requirements and assist you in every step of the way. Don't let power quality issues impair your systems - get in touch with us now to learn how we can help!